HPLC & HILIC Column: Improved Separation of Diquat & Paraquat

  
  
  
  
  
  

separation of diquat Recently, the Chinese govt announced that they will phase out the use and manufacture of the highly poisonous herbicide paraquat and the govt will cancel the registration and production license for paraquat by July 1, 2014. According to the facts about paraquat page on the US CDC site, ingestion of small to medium amounts of paraquat can result in liver, kidney, or heart failure plus scarring to the lungs. Research has also shown is being linked to the development of Parkinson's disease. The EU banned paraquat in 2007, and many other countries, such as Malaysia have banned paraquat with now China following suit.

Paraquat mixed with diquat was used for a long time around the world to control crop and aquatic weeds. High-performance liquid chromatography (HPLC) is one commonly used method for the determination of diquat and paraquat. The U.S. Environmental Protection Agency (EPA) has published EPA Method 549.2 (downloadable PDF), a method for the determination of these herbicides in aqueous samples by liquid-solid extraction and high performance liquid chromatography (HPLC) with ultraviolet detection.

Here, we present Application Brief 114, Improved Separation of Diquat and Paraquat Using the Acclaim Mixed-Mode HILIC-1 Column, (downloadable PDF) describing an efficient method for the baseline separation of diquat and paraquat with improved peak shape. The experiment was performed using a 3 μm LC column that combines Reversed-Phase and Hydrophilic Interaction Phases  (Thermo Scientific Acclaim Mixed-Mode HILIC-1 column) and our rapid separation liquid chromatography (RSLC) system (Thermo Scientific Dionex UltiMate 3000 RSLC system). Note that the separation of diquat and paraquat is difficult due to their very weak retention on a conventional reversed-phase C18 column; therefore, ion-pairing reagents are added to the mobile phase. These reagents are also added to improve peak shape.

The blog also features many other environmental applications for the determination of  herbicides, pesticides, and POPs. Check out the Browse by Tag on the lower right of this post to see the various categories. Also, don't forget to comment in the Comment Box below if this application was of interest to you or you are interested in another application. Our experts will be pleased to answer your questions.

Comments

How to purchase the Acclaim mixed- mode HILIC -1
Posted @ Monday, July 02, 2012 1:34 AM by MK Wong
Hello. Thanks for your inquiry about the Acclaim Mixed-Mode HILIC-1, 3.0 × 150 mm, 3 μm (P/N 070090). You can order this column by contacting our order desk at 1-800-346-6390. If you have any other questions, please feel free to contact me. My information is listed below. 
 
 
 
Peter 
 
 
 
Peter Bodsky 
 
Field Marketing Manager, Dionex 
 
Products 
 
North American Sales & Service  
 
 
 
Thermo Fisher Scientific 
 
1228 Titan Way 
 
Sunnyvale, CA 94088 
 
 
 
(408) 202-3270 Office 
 
(408) 735-9930 Fax 
 
Peter.Bodsky@Thermofisher.com 
 
www.thermoscientific.com/dionex 
 
Posted @ Friday, July 06, 2012 1:21 PM by Tanya Tran
Post Comment
Name
 *
Email
 *
Website (optional)
Comment
 *

Allowed tags: <a> link, <b> bold, <i> italics